SDI and Turbidity: Setting RO Feed Water Limits

HydroWorks Engineering Team 8 min read Updated

Quick answer

Silt density index and turbidity are often quoted together, but only one of them predicts how fast an RO membrane will foul. SDI measures filter plugging over 15 minutes; turbidity measures light scatter. This guide explains the test, the limits that matter and the pretreatment steps that bring a bad feed into specification.

Three FRP pretreatment vessels in a water treatment room
01

What is SDI and how is the test run?

SDI, the silt density index, measures how fast a 0.45 µm membrane filter plugs under a fixed pressure. The standard test uses a 47 mm disc, 2.1 bar (30 psi) and a 500 mL sample. The time to collect the first 500 mL is recorded, then the time to collect a second 500 mL after 15 minutes of flow. SDI15 equals (1 − t1/t2) × 100 / 15, expressed as percent per minute. A higher value means faster plugging, and a value above 5 means the water is not acceptable for most RO membranes without further pretreatment.

The test is deliberately crude. It responds to particles in the 0.1–10 µm range, which is where colloids, algae fragments and iron flocs sit. It is not a particle count and not a measure of dissolved organics. Two waters can both read SDI15 4.5 and foul a membrane at different rates, because the composition of the foulant differs. Use SDI as a pass or fail gate, not as a precise design number.

  • Filter disc: 0.45 µm, 47 mm diameter, held in a clean support
  • Pressure: 2.1 bar, or 30 psi, held constant for the whole test
  • Timing: t1 for the first 500 mL, t2 for 500 mL after 15 minutes
  • Result: SDI15 above 5 fails most membrane specifications
02

Why is turbidity a weak predictor of membrane fouling?

Turbidity measures light scattered by suspended particles, usually reported in NTU. It is dominated by particles around 1 µm and larger, and it is insensitive to the submicron colloids that pack tightly into a membrane spacer. Water at 0.3 NTU can still carry enough colloidal silica or iron to foul an array, while water at 1.2 NTU of coarse silt may be removed easily by a 5 µm cartridge.

Turbidity is still useful: it is continuous, cheap and fast, and it catches upsets such as filter breakthrough. The mistake is treating a low NTU as permission to skip SDI measurement. Turbidity tells you whether the filter is working now; SDI tells you whether the water is safe for the membrane over months.

Turbidity also depends on the instrument. A portable meter and an online probe can differ by 0.1–0.3 NTU on the same sample, which matters when the limit is 1 NTU. Calibrate against a formazin standard and use the same instrument for trend comparison.

03

What SDI and turbidity limits do RO membranes need?

The limits below reflect common membrane warranty conditions, not a single universal standard. The enforceable values are in the element datasheet and the project warranty. What matters is that SDI and turbidity are only two of several limits: a design that meets both while missing chlorine or iron still fails in the first year.

Typical RO feed water limits
ParameterTypical limitReason
SDI15Below 5, target below 3Colloidal and particulate fouling
TurbidityBelow 1 NTU, below 0.2 after UFParticulate load on the cartridge and membrane
Free chlorineBelow 0.1 mg/LIrreversible oxidation of polyamide
IronBelow 0.1 mg/L, preferably 0.05Iron oxide fouls the feed spacer
ManganeseBelow 0.05 mg/LBlack oxide deposits, hard to clean
HardnessSoften above 120 mg/L as CaCO₃ when recovery exceeds 65%Calcium carbonate and sulphate scaling
SilicaKeep concentrate below 100–150 mg/L at 25 °CSilica polymerises and is hard to remove

Limits vary by element type and recovery. Confirm against the selected membrane datasheet.

04

Which pretreatment lowers SDI most?

Coagulation with a metal salt or polymer, followed by multimedia filtration, typically brings SDI15 from 6–8 down to 3–5. Ultrafiltration, with a nominal pore size of 0.01–0.1 µm, typically delivers SDI15 below 3 and turbidity below 0.1 NTU, and it does so more consistently than media filters when the raw water changes. A 5 µm cartridge after either step is a guard, not a treatment stage: it protects the membranes from a media upset but does not lower SDI by itself.

Typical SDI and turbidity by treatment stage
StageTypical SDI15Typical turbidityNote
Raw surface water6–85–20 NTUSeasonal; test after rain
Coagulation + multimedia3–5Below 1 NTUDose and mixing control are critical
Ultrafiltration1–3Below 0.1 NTUVerify module integrity, not only turbidity
RO feed targetBelow 5, ideally below 3Below 1 NTUPlus chlorine, iron and hardness limits
05

How do you troubleshoot an SDI that will not come down?

Start with the test itself. A dirty filter holder, a damaged disc, a leaking O-ring or a pressure that drifts below 2.1 bar will all produce a wrong number, and the operator will then chase a pretreatment problem that does not exist. Clean the holder, use a new disc, confirm the pressure and record the water temperature before changing any dose.

If SDI rises only after a backwash, the problem is the backwash sequence, not the media. Check the backwash flow, duration and the settling time before the filter returns to service.

  1. 01

    1. Test at each stage

    Sample raw, after multimedia, after the cartridge and after UF. The stage where SDI jumps identifies the problem.

  2. 02

    2. Check coagulation

    Underdosing leaves colloids; overdosing carries polymer onto the membrane. Run a jar test rather than adjusting the pump by feel.

  3. 03

    3. Inspect the media

    Look for channelling, bed loss and a backwash that is too short or too weak. Media that has not been backwashed properly passes its own fines.

  4. 04

    4. Check for organics and algae

    Seasonal algae raise SDI without raising turbidity much. Chlorination and dechlorination, or coagulation, are the usual responses.

  5. 05

    5. Verify the cartridge

    A 5 µm cartridge that is bypassing or has collapsed is not protecting anything. Check differential pressure and the housing seals.

06

How often should SDI be measured?

Measure SDI15 at commissioning and after any change in source, media or pretreatment. In operation, daily on surface water and weekly on stable municipal or well water, plus after every media replacement and after any turbidity upset. For the formal test, take three readings at 5, 10 and 15 minutes and report the 15-minute value; a single reading hides variability. Log temperature with the result, because SDI rises as water warms and flow changes.

07

Can ultrafiltration replace the SDI test?

UF produces water that usually passes the SDI limit, but it does not replace the measurement. Membranes can break, modules can leak at the O-rings, and a UF that passes 0.1 NTU can still pass colloids during a fibre break. Keep SDI as a periodic check and use continuous turbidity and particle counting as the early warning. The combination is stronger than either test alone.

A UF skid also produces its own waste stream: backwash and chemically enhanced backwash typically reject 5–15% of the feed, and that volume belongs in the water balance before the RO is sized.

08

What other feed limits matter as much as SDI?

Chlorine is the most destructive: polyamide membranes tolerate less than 0.1 mg/L of free chlorine, and the damage is irreversible. Iron and manganese foul the spacer, hardness and silica scale the concentrate end, and temperature sets both flux and solubility. A feed that passes SDI but carries 0.5 mg/L chlorine will fail faster than a feed with SDI 5 and no oxidant.

  • Free chlorine below 0.1 mg/L, or ORP below 200 mV at the membrane inlet
  • Iron below 0.1 mg/L and manganese below 0.05 mg/L
  • Soften when hardness exceeds 120 mg/L as CaCO₃ at recovery above 65%
  • Keep silica in the concentrate below 100–150 mg/L at 25 °C
  • Design between 15 and 30 °C; correct flux by about 3% per °C

FAQ

Frequently asked questions

Questions buyers actually ask during sizing and quotation. Answers match the specifications above.

01 What SDI is acceptable for an RO system?
Most membrane manufacturers require SDI15 below 5 and recommend below 3 for surface water. Below 3 is the practical target for systems that must run for years between cleanings. Above 5, add coagulation, multimedia filtration or ultrafiltration.
02 Is SDI the same as turbidity?
No. Turbidity measures light scatter by suspended particles, mainly above 1 µm. SDI measures the plugging rate of a 0.45 µm filter and is sensitive to submicron colloids. Low turbidity does not guarantee acceptable SDI.
03 Can a 1 µm cartridge fix a high SDI?
Only marginally. A cartridge is a guard filter, not a colloid removal stage. It catches particles that break through upstream treatment, but it cannot remove the submicron colloids that drive SDI. Fix the pretreatment instead.
04 Why does SDI change with water temperature?
Warmer water has lower viscosity, so it passes the 0.45 µm disc faster and the measured times change. The test is normally reported with the temperature, and comparisons should be made at similar conditions, usually near 25 °C.
05 How long does the SDI test take?
The flowing test itself takes 15 minutes, plus setup, flushing and cleaning of the holder. Budget 30 minutes per sample including preparation. The first 500 mL usually takes under a minute on clean water.
06 Does ultrafiltration guarantee SDI below 3?
Typically yes, when the modules are intact and the flux is controlled. It is not a guarantee: fibre breaks and O-ring leaks pass colloids. Verify integrity with pressure decay or turbidity, and keep periodic SDI checks.
07 SDI is fine but differential pressure keeps rising. Why?
Look beyond particles: biofilm, organic fouling and iron or manganese oxides all raise differential pressure without moving SDI much. Check chlorine or ORP, iron, TOC and the cleaning history before adding more filtration.