On-site ozone · 1–3 mg/L · oxidation and disinfection
Ozone Water Treatment System — Generation, Contacting and Off-gas Destruction
Quick answer
An ozone water treatment system generates ozone from air or oxygen, dissolves it through a venturi or contact tower, and destroys the off-gas. Ozone oxidises iron, manganese, colour and taste compounds and inactivates microorganisms, then decays within minutes, leaving no measurable residual. Dose and contact time depend on the target contaminant and local rules.
- Drinking water dose
- 1–3 mg/L Drinking water dose
- Bottle rinse dose
- 2–4 mg/L Bottle rinse dose
- Typical contact time
- 5–15 min Typical contact time
- Oxygen feed purity
- 90–95% Oxygen feed purity
01
What is an ozone water treatment system and how does it work?
An ozone system generates ozone on site from dry air or oxygen, dissolves it into water, contacts it long enough to oxidise the target compounds, and destroys the ozone left in the vent gas. Ozone is produced by corona discharge across a dielectric inside a stainless reactor. It cannot be stored, so generation is matched to demand.
A complete train is feed-gas preparation, generator, injector, contact vessel, off-gas destructor, and controls that read ORP or dissolved ozone. Ozone is an oxidant, not a filter: it converts dissolved iron, manganese, colour and taste compounds into forms that filtration or carbon can remove.
Commercial generators range from about 10 g/h for a small drinking point to several kg/h for a plant. The rating is always stated at a defined oxygen concentration, dew point and cooling temperature, so compare quotations on the same basis.
02
Should I choose an oxygen-feed or air-feed ozone generator?
Air feed is simpler: a compressor, dryer and filter supply the generator, and the ozone concentration is typically 1–3% by weight. Oxygen feed from a PSA or liquid source raises concentration to 6–12% and reduces the gas volume through the reactor, which improves transfer efficiency and lowers power per kilogram of ozone.
Air feed suits small and medium outputs; oxygen feed becomes more economical as capacity rises and is easier to control at high dose. The trade-off is the oxygen supply itself: PSA units add power and maintenance, while liquid oxygen adds deliveries and storage. For the same output, oxygen feed also reduces the size of the contact tower and the destructor.
| Aspect | Air feed | Oxygen feed |
|---|---|---|
| Ozone concentration | 1–3% by weight | 6–12% by weight |
| Feed preparation | Compressor, dryer and filter | PSA oxygen or liquid oxygen |
| Specific energy | 14–22 kWh/kg O₃ typical | 7–12 kWh/kg O₃ typical |
| Typical output | Small to a few hundred g/h | Hundreds of g/h to kg/h |
| Typical use | Small plants, intermittent duty | High output, high dose, continuous duty |
Typical industry values. Confirm the generator rating at the actual dew point, cooling water temperature and altitude.
03
How is ozone injected and contacted?
Ozone must dissolve, not bubble through. A venturi injector creates a vacuum that draws gas into the water stream, and a static mixer or contact tower gives the bubbles time to transfer. Counter-current towers with a diffuser at the bottom and water entering at the top reach high transfer efficiency; bubble columns are simpler but taller. Transfer depends on bubble size, water depth and temperature; the undissolved fraction goes to the destructor.
Contact time is usually 5–15 minutes for drinking water, longer for iron and manganese oxidation. The vessel must be vented to an ozone destructor, and the water should be degassed before it reaches a storage tank or carbon bed. The injector is sized for peak water flow and gas-to-liquid ratio; too much gas at low flow creates foam and poor transfer.
04
What ozone dose is used for drinking water and bottled water?
Dose is set by the contaminant and the ozone demand of the water, not by a single figure. Drinking water typically uses 1–3 mg/L; bottle rinsing uses 2–4 mg/L; iron and manganese removal needs enough to oxidise the metal plus the immediate demand. Measure the demand with a bench test: add ozone, wait, and measure what remains.
| Application | Typical dose | Contact | Notes |
|---|---|---|---|
| Drinking water disinfection | 1–3 mg/L | 5–15 min | Residual after contact per local rule |
| Bottled water rinsing | 2–4 mg/L | 1–5 min | Rinse water, not the filled product |
| Iron and manganese oxidation | 1–3 mg/L | 5–15 min | Followed by filtration |
| Colour and taste removal | 1–3 mg/L | 5–15 min | Carbon polishing may follow |
| Storage protection | 0.2–0.5 mg/L residual | Recirculation | Monitor with ORP or ozone sensor |
Typical ranges only. Actual dose depends on ozone demand, temperature, pH and the target removal; verify by testing.
05
How do you size an ozone generator for a water flow?
Generator output in grams per hour equals water flow in cubic metres per hour multiplied by the ozone dose in milligrams per litre, then divided by the transfer efficiency. One cubic metre per hour at 1 mg/L requires 1 g/h before losses. A 10 m³/h stream at 2 mg/L therefore needs 20 g/h at 100% transfer, or about 22–25 g/h at 80–90% transfer.
The dose must be based on the ozone demand of the water, not only the target residual. Demand is measured by a bench test: dose a sample, wait the contact time, and measure the residual. High iron, manganese, colour or nitrite consumes ozone before disinfection begins. Add the demand to the target residual before selecting the generator.
| Input | Typical value | How it is used |
|---|---|---|
| Water flow | Peak flow in m³/h | Basis of the calculation |
| Ozone dose | 1–3 mg/L for drinking water | Target residual plus demand |
| Ozone demand | 0.5–2 mg/L, measured by bench test | Consumed by iron, manganese, colour and organics |
| Transfer efficiency | 80–95% with a venturi and contact tower | Divides the required generator output |
| Generator capacity | Flow × dose ÷ transfer efficiency | Select the next standard generator size |
| Contact time | 5–15 minutes for drinking water | Sets the contact tower volume |
| Off-gas destruction | Sized for undissolved ozone | Safety and odour control |
Worked example: 10 m³/h × 2 mg/L = 20 g/h at 100% transfer; at 90% transfer select about 22 g/h. Confirm with the actual demand test.
06
What is the CT value and why does it matter?
CT is the product of dissolved ozone concentration and contact time, usually written mg·min/L. One mg/L held for ten minutes gives a CT of 10. It matters because ozone is consumed by the water before it acts on microorganisms: the CT that counts is the residual after demand, not the dose at the injector. Temperature, pH and the target organism change the CT required.
Measure dissolved ozone at the outlet, not only at the inlet, and calculate CT for the actual flow and vessel volume. A longer contact time can compensate for a lower residual, within the limits of the vessel. For example, a tower holding 5 m³ at 10 m³/h gives a nominal 30-minute contact time; a residual of 0.4 mg/L after demand gives a CT of 12 mg·min/L.
07
Does ozone leave a residual, and how does it compare with UV?
Ozone decays to oxygen, with a half-life of roughly 20–30 minutes in clean water at 20 °C and much less in water carrying organics or metals. It leaves no persistent residual in the distribution network, so it protects the contact vessel and the tank but not a long loop. UV acts only while water passes the lamp and also leaves no residual.
Ozone is an oxidant and can remove colour, taste and metals; UV is a photochemical disinfectant and removes none of those. Ozone can form bromate where bromide is present; UV at 254 nm does not. Use ozone before filtration and storage, UV at the point of use.
08
What safety measures are required for ozone?
Ozone is toxic and corrosive. Ventilate the generator room, monitor ambient ozone with an alarm, and route all vent gas through a destructor. Ozone is heavier than air and collects at low level, so place sensors near the floor and at the generator. Interlock the gas detector to the generator and an exhaust fan.
Use 316L stainless steel, PTFE, PVDF and ozone-resistant elastomers for wetted parts; ordinary rubber and some plastics crack. Post warning signs, train operators, and never run the generator in a closed room without ventilation. Do not rely on smell: some people detect ozone below the occupational limit, others only above it.
09
What maintenance does an ozone system need?
Maintenance centres on the feed gas and the destructor. Replace the dryer desiccant and filters on schedule, keep the dew point low, clean the generator cooling circuit, and calibrate the ozone or ORP sensor. Replace the destructor catalyst or check the heater annually. Keep spare fuses, solenoid valves and sensor membranes: most shutdowns are feed-gas or instrument faults, not generator failure.
- Check for leaks with an ozone monitor at every service.
- Clean the injector and contact tower when transfer efficiency falls.
- Log generator hours, dew point, dissolved ozone and destructor outlet.
Specifications
Delivery and service — typical ranges
| Item | Typical range |
|---|---|
| Standard skid lead time | 15–30 days after drawing approval |
| Containerized / turnkey lead time | 30–60 days after drawing approval |
| Warranty | 12–18 months from shipment |
| Factory testing | Hydrostatic pressure test and trial run with water before packing |
| Documentation | General arrangement drawing, P&ID, test record, O&M manual and spare-parts list |
| Packaging | Seaworthy plywood crate, or container for containerized plants |
| Installation support | Remote guidance as standard; on-site engineer available on request |
| Operator training | 1–2 days at commissioning, covering operation, CIP and consumables |
| Spare parts | Recommended two-year list quoted separately with the equipment |
| Payment terms | Typically 30% deposit and 70% before shipment; confirmed in the quotation |
| Minimum order | 1 unit |
| Loading port | Guangzhou or Shenzhen, China |
| Power supply | 220/380/415/440 V, 50/60 Hz; confirmed on order |
| Ambient temperature | 5–40 °C |
| Enclosure protection | IP54 for indoor skids; higher IP available on request |
| Certification | CE and ISO 9001; model-specific test reports on request |
Typical industry ranges for planning. Final scope, commercial terms and lead time are confirmed in the quotation.
FAQ
Frequently asked questions
Questions buyers actually ask during sizing and quotation. Answers match the specifications above.
01 Is ozone safe in drinking water?
02 Ozone or UV — which disinfection do I need?
03 Does ozone remove iron and manganese?
04 Why is the off-gas destroyed?
05 How long does ozone last in water?
06 Can an air-feed generator handle high output?
07 What contact time does ozone need?
08 Does ozone change pH or TDS?
Next step
Send your water analysis, get a factory quotation
Tell us the source water, TDS, hardness, iron and daily demand. Factory engineers reply with a flow rate, process train and budget range within one working day.